Q: What do I do if my radiator panel is leaking?

This is due to the metal corroding/rusting, and the first sign of it happening is that the floor under the radiator gets wet when the heating is on. The first thing to do is to turn off both radiator valves to stop any more fluid being lost from the pipe system, which can affect the boiler and the rest of the radiators. Place a container under the radiator to catch any more drips of fluid.

If you don't have any plumbing knowledge it would be more cost effective to employ a qualified plumber/heating engineer to do the work required - the immediate emergency has been dealt with, and you can afford to get some quotes for the work to be done. It shouldn't cost an arm and a leg, as radiator panels are readily available for most plumbing merchants if it's a standard style (i.e. a flat straight panel, not once that has been bowed for a curved wall like a bay window). So for the cost of the radiator panel and a few hours' labour time, the work should be completed to a satisfactory level.

For those of you who feel they have good mechanical experience and the correct tools, then you may want to attempt it yourself. Firstly you will have to measure the width and height of the radiator panel, and determine the style of radiator. If you're not sure, stand as close as possible to it, look directly down at the top and take a photo of the top edge. Show the assistant at the plumbing merchant and they'll be able to give you a similar one.

Once you have purchased the radiator you will need to drain the old one and dismantle the fittings. The tools required for the change-over are a masonry drill and drill-bit of the appropriate size for the wall plug you will be using (red wall plugs and a 6mm masonry drill-bit for example). Use pozi-drive screws rather than slotted head ones, as there's less chance of the screwdriver slipping. When using the driver, the screw should be at least an inch and a half to two inches long for large radiators.

For plasterboard walls a toggle bolt is one of the many fixings suitable for this type of wall. You'll need two adjustable spanners, a radiator bleed key and possibly a radiator valve key (this looks like an oversized Allen key). With the two adjustable spanners, one is used to hold the top of the radiator valve (with the head taken off) to stop it rocking on the pipe when you undo the nut to panel connection. For draining and disconnection, if you have a combination boiler turn the heating controls off so that the heating system cools down before starting on the replacement. Then after changing the radiator you will need to repressurise the system to 1 Bar for up to 10 radiators. If you have a standard or back boiler the heating controls still need to be off, so that the pump is not running when you refill the exchanged radiator.

Before starting to drain you might want to put a bin liner on the floor with an old towel on top to catch any spills you might get under the radiator valve. When the radiator starts to drain from the nut you will need to open the little air bleed at the top on one end to allow all the fluid to drain out. When this has finished, again put a bin liner and old towel under the the other radiator valve. Now you can undo both valve-to-panel nuts all the way.

With these nuts undone, and depending on the size of the radiator you will have to gently move the pipes with the valves on towards the wall to enable you to put your thumb over the hole that will be there on the radiator. Lift the radiator off the brackets, keeping your thumbs over the holes and the radiator vertical so that it can be taken to a safe area to drain any sludge that occurs at the bottom of the radiator down a sewer drain.

The new radiator can be dressed with the new fittings for the top and the old fittings at the bottom. As for the joining of the new radiator and valves, it will have to be hung on new brackets. Then you can join the valves and the panel together via the nuts, again using the two adjustable spanners to do up the valve nuts in the same way you undone them. Make sure that the new air bleed at the top of the radiator is shut, and open both radiator valves at the same time to allow the pressure from both pipes to refill the radiator panel. You can then bleed the air from the valve at the top at one end until water comes out. For a combination boiler you will need to refill the system to 1 Bar, via the filling point directly under the boiler. With the pressure obtained turn the filling point off. With a standard/back boiler this will self-fill from the little plastic container in the loft. With the radiator bled of air it will be safe to turn the heating controls back on and get the radiators hot again.

- Mark Lewis

 

After reading this are you tempted to have a go at this or various other DIY tasks yourself? Or even considering a new career as a professional plumber? At Access Training we provide a number of professional plumbing courses suitable for whether you're looking to gain industry-standard qualifications and become a plumber or simply looking to gain some new skills for your home renovation projects. For more information contact us on 0800 345 7294.

The Government has sparked more frustration from industry members as it announced yet another delay to the start of the long-awaited Renewable Heat Incentive (RHI).

The scheme, which was designed to encourage renewable heating systems to be installed in domestic properties and offer money towards those who have fitted renewable heating products, was meant to launch this Autumn but has now been pushed back until Spring 2014.

Greg Barker, the Energy and Climate Change Minister, said: "The RHI, which has been available for non-domestic investors for over a year, is a key part of our approach to cutting carbon and driving forward the move to more sustainable low carbon heating alternatives."

"We remain committed to introducing an incentive scheme for householders too, and have set out an updated timetable for its launch alongside new plans to extend our renewable heat voucher scheme in the meantime."

However this isn't enough for many leading industry members, who have vocally expressed their disappointment at the delay. Jim Moore, of leading heating and boiling manufacturers the Vaillant Group has said: "The Government now needs to deliver on its latest deadline to assist in stimulating increased uptake of renewables in the UK as has been demonstrated as effective in so many European markets."

Elsewhere, chief executive of the Micropower Council Dave Sowden has commented: "Taken with the delay in confirmed the next steps of the 'zero carbon homes' policy, the announcement is forcing the industry to question whether the Coalition is serious about promoting domestic renewable heat during this Parliament."

Coinciding with this announcement was also an action plan looking at the potential to cut emissions from heat across the whole of the UK economy. It focuses on a number of key actions in an attempt to spur on the move to low carbon heating alternatives and drive forward green growth. These include;

  • A £9 million package to help local authorities get heat network schemes up and running in towns and cities across the country, with a new Heat Networks Delivery Unit to sit within the Department of Energy and Climate Change (DECC) providing expert advice.
  • £1 million for Manchester, Leeds, Newcastle, Sheffield and Nottingham to help them develop heat networks.
  • 100 green apprenticeships to be funded primarily for young people in small scale renewable technologies.
  • Up to £250,000 for a new first-come-first-served voucher scheme for heating installers to get money off the cost of renewable heating kit installation training, with up for £500 or 75% of the cost of the training per person.
  • Working with individual industrial sectors to design long-term pathways to cut carbon across UK industry.

Get in touch to learn more about our training courses!

First Name *
Surname *
Telephone Number *
E-mail address *
Ask A Question *
 
Security Character Security Character Security Character Security Character Security Character Security Character
Enter Letters (No Spaces) *